IonSense DART Ion Source – Direct Analysis in Real Time Mass Spectrometry

₹55000.00₹65000.00

IonSense DART (Direct Analysis in Real Time) Ion Source Assembly designed for ambient ionization mass spectrometry applications. Suitable for rapid chemical screening, pharmaceutical research, forensic analysis, and laboratory testing. Features a specialized cylindrical housing, metallic mounting assembly, and integrated cable connections. Compatible mass spectrometry system required.

Product Description - IonSense DART Ion Source – Direct Analysis in Real Time Mass Spectrometry

The IonSense DART Ion Source Assembly is a specialized analytical instrument component designed for Direct Analysis in Real Time (DART) mass spectrometry applications. It is used as an ionization source in mass spectrometry systems, allowing researchers and analytical laboratory professionals to examine chemical compounds directly from samples with minimal sample preparation.

DART technology is an ambient ionization technique that enables the rapid analysis of various chemical substances under atmospheric conditions. Unlike conventional analytical approaches that may require extensive sample extraction, separation, or preparation, DART technology allows suitable samples to be introduced directly into the ionization region for analysis.

The IonSense DART source operates by generating excited gas species through an electrical discharge process. These excited species interact with molecules present on or released from the sample surface, resulting in the formation of ions that can subsequently be detected by a compatible mass spectrometer. This approach makes DART particularly useful for rapid screening and identification of chemical compounds.

The equipment shown in the photograph features a blue cylindrical housing, a metallic mounting assembly, and integrated electrical cables. These components form part of the source assembly and its connection and mounting arrangement. The construction is intended for integration with a compatible mass spectrometry instrument.

One of the major advantages of DART technology is its ability to perform direct sample analysis without requiring conventional chromatographic separation in many applications. This can help reduce sample preparation time and support faster analytical workflows.

The IonSense DART ion source can be used in research laboratories, pharmaceutical testing facilities, forensic laboratories, chemical analysis centres, and academic research institutions. It is particularly relevant for laboratories performing rapid chemical identification, material screening, pharmaceutical analysis, and forensic investigations.

In pharmaceutical research, DART-MS technology can support the investigation of active pharmaceutical ingredients, excipients, degradation products, and other chemical constituents. It can also assist in rapid screening of raw materials and finished products when the analytical method has been appropriately validated.

For forensic applications, DART technology is useful for screening unknown substances, pharmaceuticals, narcotics, and other chemical materials. Its ability to analyse suitable samples directly makes it valuable for laboratories requiring rapid preliminary chemical identification.

The instrument is designed to work with compatible mass spectrometry interfaces. Depending on the system configuration, it may be integrated with different mass spectrometer platforms. Compatibility must be checked against the specific source configuration and instrument interface before installation.

The visible cylindrical body and associated cables indicate a dedicated instrument assembly rather than a standalone general-purpose laboratory device. It should therefore be considered an accessory or ionization source component for an appropriate mass spectrometry system.

The IonSense DART ion source is a valuable component for laboratories looking to perform ambient ionization mass spectrometry and rapid chemical screening. Its specialized design supports analytical workflows where speed, reduced sample preparation, and direct chemical analysis are important.

Important: The exact model, operating voltage, gas requirements, temperature range, and instrument compatibility should be verified against the equipment identification plate and original manufacturer documentation before purchase or installation.

2.2 Applications of Product

  1. Pharmaceutical research and drug identification.

  2. Forensic chemical analysis and substance screening.

  3. Rapid identification of unknown chemical compounds.

  4. Food safety and food contaminant screening.

  5. Chemical and material characterization.

  6. Environmental sample screening.

  7. Pharmaceutical raw material analysis.

  8. Research and development laboratory applications.

  9. Detection and screening of suitable organic compounds.

  10. Ambient ionization mass spectrometry research.

2.3 Features of Product

  • Direct Analysis in Real Time (DART) technology.

  • Designed for ambient ionization mass spectrometry.

  • Supports rapid chemical screening.

  • Enables direct analysis of suitable samples.

  • Can reduce conventional sample preparation requirements.

  • Specialized cylindrical source assembly.

  • Integrated electrical cable connections.

  • Metallic mounting and interface components.

  • Designed for compatible mass spectrometry systems.

  • Suitable for research and analytical laboratories.

2.4 Technical Specifications

Specification Details
Brand IonSense
Product type DART Ion Source
Technology Direct Analysis in Real Time
Application Mass spectrometry
Ionization technique Ambient ionization
Equipment category Mass spectrometry accessory
Housing Blue cylindrical housing
Construction Metal and engineered housing components
Connections Integrated electrical cables
Mounting Dedicated mounting/interface assembly
Model To be verified
Part number Not visible
Gas requirement Refer to model-specific manual
Operating temperature To be verified
Electrical requirements To be verified
Compatibility Compatible DART-MS platform required

2.5 Product Condition

Condition: Used / Refurbished – To be confirmed

The actual working condition, functionality, completeness, and testing status should be confirmed before publishing.

Why Buy IonSense DART Ion Source – Direct Analysis in Real Time Mass Spectrometry?

Our refurbished IonSense DART Ion Source – Direct Analysis in Real Time Mass Spectrometry offers exceptional value without compromising on quality. Each unit is thoroughly tested, quality-verified, and comes with certification — making it a reliable choice within our Part and Accessories range.

IonSense DART Ion Source – Direct Analysis in Real Time Mass Spectrometry Price in India

Get the best IonSense DART Ion Source – Direct Analysis in Real Time Mass Spectrometry refurbished price in India with Techtom. We offer competitive pricing, fast delivery across India, and trusted after-sales service. Compare our prices and save up to 60% compared to brand new equipment.

Key Features & Specifications

  • Quality Tested: Every unit undergoes rigorous testing
  • Certified & Refurbished: Complete transparency in condition
  • Warranty Included: Peace of mind with coverage
  • Cost-Effective: Save significantly on equipment costs
  • Eco-Friendly: Sustainable alternative to new equipment

Who Should Buy This Equipment?

Ideal for businesses, institutions, and professionals looking for dependable part and accessories solutions. Techtom's refurbished equipment offers an affordable and sustainable alternative to buying new.

Shipping & Delivery

Free shipping available across India. Secure packaging ensures equipment arrives in perfect condition. Fast delivery within 3-7 business days.

Frequently Asked Questions

What is the price of IonSense DART Ion Source – Direct Analysis in Real Time Mass Spectrometry?

The price varies based on condition, included accessories and warranty coverage. Contact us for the latest pricing and availability.

Is a refurbished IonSense DART Ion Source – Direct Analysis in Real Time Mass Spectrometry as reliable as a new one?

Yes, every refurbished IonSense DART Ion Source – Direct Analysis in Real Time Mass Spectrometry unit is professionally inspected, cleaned and functionally tested before dispatch to ensure reliable performance.

What accessories are included with IonSense DART Ion Source – Direct Analysis in Real Time Mass Spectrometry?

Included accessories may vary depending on stock availability. Please check the product listing or contact us for exact details.

Does this refurbished unit come with a warranty?

Warranty coverage may vary by unit. Please verify warranty terms at the time of purchase.